Testo 340 NO / NO2 Kit

£2,990.00 £3,588.00 (inc. VAT)
Stock Status: In Stock
Information

Testo 340 NO / NO2 Kit

Order number 0563 9350 Price £2,990.00

  • Can measure O2, CO, NO, NO2

  • Extended measuring range for use in environments with high gas concentrations
  • Precalibrated gas sensors for quick and easy sensor change
  • Integrated pressure difference and air flow measurements for mass flow calculations

Emission checks in industry: Professional technology meets practical design. The testo 340 combustion analyser is an easy-to-use flue gas analyser that can be fitted with up to four different gas sensors

Product Description

Precise technology: That’s what you want to be able to rely on when you’re working out in the field. But precise technology is nothing if it is not versatile, easy to use and adaptable for use in the field. The testo 340 flue gas analyser ticks all these boxes.
The testo 340 combustion analyser. For industrial emission measurements and more

Which sensors do you need in the course of your daily work and which measurements do you normally need to carry out? The testo 340 comes standard-fitted with an O2 sensor and four more sensors (CO, NO, NOlow, NO2 or SO2) for you to choose from, allowing you to customise your analyser to suit your individual demands. The analyser’s compact design and the reliable technology tucked away inside ensure increased mobility, making it ideal for use in international service operations and for installing or carrying out checks on firing plants or energy production systems. To find out more about the different application possibilities and to see which industrial applications your testo 340 flue gas analyser is suitable for just click on the “Applications” tab.
High gas concentrations? No problem with the testo 340!

The flue gas analyser has an extended measuring range which allows you to carry out measurements even when gas concentrations are very high (i.e. during industrial flue gas analysis). The extended measuring range (thinning) is activated automatically when high gas concentrations suddenly occur. The demands on the sensor are no different to when the flue gas analyser is used in low gas concentrations.

Available in 3 different kit configurations

Differential Pressure - Piezoresistive

Measuring range

-200 to 200 hPa

Accuracy

±0.5 hPa (-49.9 to 49.9 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.1 hPa

Absolute Pressure

Measuring range

+600 to +1150 hPa

Accuracy

±10 hPa

Resolution

1 hPa

Flue gas O

Measuring range

0 to 25 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.01 Vol.%

Reaction time t₉₀

< 20 s

Flue gas CO (with H-compensation)

Measuring range

0 to 10000 ppm

Accuracy

±10 ppm or ±10 % of mv (0 to 200 ppm)

±20 ppm or ±5 % of mv (201 to 2000 ppm)

±10 % of mv (2001 to 10000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 40 s

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K.

Resolution

0.1 ppm

Reaction time t₉₀

< 40 s

Flue gas NO

Measuring range

0 to 4000 ppm

Accuracy

±5 ppm (0 to 99 ppm)

±5 % of mv (100 to 1999 ppm)

±10 % of mv (2000 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

< 30 s

Flue gas Nolow

Measuring range

0 to 300 ppm

Accuracy

±2 ppm (0 to 39.9 ppm)

±5 % of mv (Remaining Range)

Resolution

0.1 ppm

Reaction time t₉₀

< 30 s

Flue gas NO

Measuring range

0 to 500 ppm

Accuracy

±10 ppm (0 to 199 ppm)

±5 % of mv (Remaining Range)

Resolution

0.1 ppm

Reaction time t₉₀

< 40 s

To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.

Flue gas SO

Measuring range

0 to 5000 ppm

Accuracy

±10 ppm (0 to 99 ppm)

±10 % of mv (Remaining Range)

Resolution

1 ppm

Reaction time t₉₀

< 40 s

To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.

Differential Pressure flue gas Draught - Piezoresistive

Measuring range

-40 to +40 hPa

Accuracy

±0.03 hPa (-2.99 to +2.99 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.01 hPa

Temperature

Measuring range

-40 to +1200 °C

Accuracy

±0.5 °C (0 to +99 °C)

±0.5 % of mv (Remaining Range)

Resolution

0.1 °C

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue gas dewpoint (calculated)

Measuring range

0 to 99.9 °Ctd

Resolution

0.1 °Ctd

Flue gas CO calculation (calculated from O)

Measuring range

0 to CO max

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 s

General technical data

Weight

960 g

Dimensions

283 x 103 x 65 mm

Operating temperature

-5 to +50 °C

Product-/housing material

TPE PC

Protection class

IP40

Product colour

Black

Connectable probes

1 x flue gas probe; 1 x temperature probe; 1 x differential pressure

Display type

graphic Display

Display size

160 x 240 pixels

Display function

Graphic display

Power supply

Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A

Max. neg. press./flue gas

-200 mbar

Max. pos. press./flue gas

50 mbar

User defined fuels

10 user-defined fuels incl. test gas as fuel

Hose length

max. 7.8 m (corresponds to two probe hose extensions)

Pump flow

0.6 l/min (regulated)

Maximum memory

100 folders

Storage per folder

Max. 10 sites

Storage per site

Max. 200 logs

Miscellaneous

The max. number of logs is determined by the number of folders or sites

Interface

Bluetooth®; USB; IR/IRDA interface; gas outlet; Mains connection; probe input/ probe inputs; Differential Pressure

Storage temperature

-20 to +50 °C

Reviews
Not yet reviewed
Write an online review and share your thoughts with other shoppers!
Be the first to review this product